Technical data
1.Externality size: 445mm*200mm*145mm
2.Max. self consumption: less and equal to 3W
3.Accuracy of temperature measuring: tolerance 2 degrees
4.Range of temperature measuring: 0-99 degrees
5.Power of controlled pumps (temperature difference circulation pump, water-using end circulation pump): less 600W
6.Electronic booster power: less and equal to 2000W
7.System working pressure: 0.6MPA
8.Input signal: 3 temperature sensors (for top of tank, for heat collector, for bottom of tank)
9.Output signal: 3 (electronic booster, temperature difference circulation pump and water-using end circulation pimp)